Do you recognise one of these symptoms?
- The RAID 0 volume disappeared after one disk failed
- The controller or motherboard was replaced and the array is no longer recognised
- Windows offers to initialise the disks
- The disks were removed and their order is unknown
- One disk is clicking or no longer detected
Job sheetRAID-0
- Device
- RAID 0 (striping)
- Price
- From €350, fixed quote after diagnosis
- Environment
- ISO 5 (class 100) cleanroom if the device must be opened
- Method
- Full image of the device, reconstruction on the copy, never on the original
- Turnaround
- Economy 10–15 working days · Standard 5–10 working days · Emergency Diagnosis in 24–48 hours
- Check
- List of recovered files sent before payment
- Confidentiality
- Data never passed to third parties, copies wiped after delivery
The faults we handle
- One disk failure
- A single failing disk is enough to take the volume offline: every file has pieces on every disk.
- Lost configuration
- A motherboard swap, BIOS update or controller reset wipes the array settings.
- Handling errors
- Disks put back in the wrong order, array recreated or a disk initialised by mistake.
What not to do
- Do not recreate the array in the BIOS or the controller utility: the new configuration overwrites the old one.
- Do not initialise any disk, even if Windows suggests it.
- Do not mix up the disk order: note their positions before removing them.
- Do not run recovery software on one disk on its own: it only holds fragments.
How RAID 0 works
Data is cut into stripes of a fixed size, usually 64 to 256 KB, written to each disk in turn. With two disks, stripe 1 goes to disk 1, stripe 2 to disk 2, stripe 3 back to disk 1, and so on. Speed and capacity add up, but reliability is divided: the chance of losing the volume grows with every disk you add.
How we rebuild a RAID 0
Every disk is first copied in full, after cleanroom repair if one of them has a mechanical fault. We then work out the three parameters of the array: disk order, stripe size and the offset where the data starts. They are found by analysing file system structures (NTFS, ext4, APFS) that cross stripe boundaries. The array is then assembled virtually, without ever writing to your disks.
The one condition is being able to read every disk. If one is beyond repair, only small files that fit inside a single stripe can be recovered.
RAID 0 simulator: what happens when a disk fails?
Blocks are striped across both disks, with no copy at all. Fault tolerance: no disk. Click one or more disks to simulate a failure.
Price of RAID 0 (striping) data recovery
From €350, fixed quote after diagnosis. The diagnosis is free and the quote is fixed: it does not change once accepted. If no data is recovered, you pay nothing. See the full price list.